In the era of high computing power, data centers face challenges in processing and storing massive amounts of data, gradually showing trends towards large-scale and high-density development, while pursuing low-carbon and intelligent operations. To meet the growing demand for computation, data centers are continuously upgrading their infrastructure, with energy efficiency management, cooling technology, and green energy conservation becoming key factors.
iTeaQ Network’s iClimate thermal management solution has shown significant results in energy conservation and emission reduction for data centers, with overall energy savings ranging between 30% and 50%. It has effectively reduced the operational costs of data centers and improved energy utilization efficiency. Moreover, the energy-saving measures of this solution have extended the lifespan of data center equipment, reduced maintenance costs, and provided a more stable and economical operating environment.
Top 2 in Competitiveness Among Data Center Air Conditioning Companies:ace
According to the “Analysis Report on the Competitiveness of Data Center Electromechanical Equipment Enterprises in the High Computing Power Era” compiled by CCID Consulting’s Electronic Information Industry Research Center, Shenzhen iTeaQ Network Technology Co., Ltd. ranks Top 2 in competitiveness among data center air conditioning companies in the high computing power era. The report points out that air conditioning is the main energy-consuming component in data centers, accounting for about 40% of energy consumption. Therefore, low-carbon and energy-efficient air conditioning products for data centers are a crucial driving force in achieving green data centers. In 2023, manufacturers on the data center air conditioning ranking list have put significant effort into releasing new low-carbon and green air conditioning products.
In August 2023, iTeaQ Network launched the “Bingding” air-cooled levitation multi-connected heat pipe cooling source system, adding a water-free application to the industry-recognized most energy-efficient technology for air-cooled server cooling. In November, they released the “Blue Ice” integrated fluorine pump natural cooling air conditioner, which not only effectively reduces the cooling CLF index but can also choose a water-free cooling method in northern regions, achieving WUE=0.
Related Technical Introduction:
The “Bingding” air-cooled levitation multi-connected heat pipe cooling source system is based on refrigerant-side fluorine pump heat pipe natural cooling technology and evaporative condensing high-efficiency heat dissipation technology. It innovatively introduces the industry’s most advanced oil-free levitation refrigeration and multi-connected system architecture, integrating ultra-high-speed variable frequency oil-free levitation technology, multi-connected refrigeration, variable frequency energy saving, AI control, and other advanced energy-saving refrigeration technologies. It is the “water-free” version of the optimal solution for air-cooled server cooling, especially for high-power AI computing servers, achieving extremely low PUE while realizing WUE=0.
The “Blue Ice” integrated fluorine pump natural cooling air conditioner is suitable for medium and large data centers with energy-saving and water-saving requirements. The system integrates fluorine pump natural cooling, large-area wind wall air supply, full variable frequency, and high return air temperature design, adopting a fully prefabricated large cooling capacity integrated design. The system uses environmentally friendly refrigerants with “dual-engine three-mode” intelligent switching. The “Blue Ice” integrated fluorine pump natural cooling air conditioner has no complex long-distance piping network and can meet various installation scenarios such as side-mounting and rooftop installation. It has advantages in energy saving, water saving, space saving, simple operation and maintenance, and rapid deployment, helping data centers achieve low PUE and potential 0 WUE operation.
These technologies have been applied in projects such as China Unicom South China Data Center, Shenzhen Ruizhi Cloud 5G and Big Data Application R&D Center, Shenzhen Lihe Media Big Data Center, Tencent Shenzhen Pingshan Data Center, and Xi’an Qinyun No.1 Data Center. Customer feedback indicates that the air-cooled levitation multi-connected heat pipe cooling source system technology is advanced, with a comprehensive and reliable architecture, strong adaptability to variable capacity, and high product innovation.
iTeaQ Network’s ranking as Top 2 in competitiveness among data center air conditioning companies in the “Analysis Report on the Competitiveness of Data Center Electromechanical Equipment Enterprises in the High Computing Power Era” is a high recognition of the brand by the industry. Looking to the future, iTeaQ Network will continue to fulfill its responsibilities as a state-owned enterprise, providing better quality services to customers and opening up broader development space for the industry.